mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Customer Interest for Dome Lamp:|M611406 > < Lighting - Interior Lights Inop. or Won't Turn OFF
Page 1
background image

Dome Lamp: Customer Interest
Electrical - Unstable A/C Fan Speed/Interior Light Inop.

SI M61 11 06
General Electrical Systems

October 2006
Technical Service

This Service Information bulletin supersedes S.M. M61 202 04 dated June 2004.

SUBJECT
BC1 Causes A/C and Interior Light Problem

MODEL
2004 MY R50 (Cooper)/R53 (Cooper S) from 03/04

SITUATION
A/C fan speed is unstable and interior light does not work

CAUSE
Incorrect BC1 installed

PROCEDURE
Check part number of installed BC1. If P/N 61 35 6 943 157 or 61 35 6 935 645, replace the BC1 using BC1 using P/N 61 35 6 949 289 or later.

PARTS INFORMATION

Customer Interest for Dome Lamp:|M611406 > < Lighting - Interior Lights Inop. or Won't Turn OFF