mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Charging System > < Tools and Equipment
Page 1
background image

Battery Cable: Description and Operation

Safety Battery Terminal And Monitoring Of The Battery Cable (shielding)

The battery cable is fitted with an electrically conducting shield, which is insulated against the body and against the battery cable. The shielding consists
of a low-impedance metal mesh. A cable exits from each end of the shielding, i.e. at the safety battery terminal in the luggage compartment and at the
battery earth point in the engine compartment. Both connection leads are connected to the airbag control module.

Safety battery terminal

The battery safety terminal is installed in the positive lead from the alternator just in front of the positive terminal of the battery. The cable ends in a
tapered plug. If the monitoring of the battery cable determines a short circuit, the safety battery terminal is triggered. This switches off the alternator and
the fuel pump.

It also deactivates the starting motor load circuit. The vehicle can no longer be started.

The interrupted generator line can be replugged provisionally to restart the engine. In this case, however, the battery terminal isolation function is no
longer available as the priming cap has already been ignited. The priming cap and alternator line must then be replaced.

Monitoring of battery cable (shielding)

The potential of the battery cable is read in via two resistors of the same size at the input of the airbag control module. If the battery cable is OK, half of
the power supply (U_V = battery voltage) is measured. In the event of a fault, different measurement values result, as shown in the following table.

If an interruption or short circuit occurs, the relevant fault memory entry is stored in the airbag control module.

NOTE:  The battery cable is only cut by the safety battery terminal in the event of a short circuit. If, for example, the outer insulation of the battery cable
is damaged but the shielding has no earth connection, the following case could occur:

Moisture (e.g. rain) can gradually reduce the voltage. A short circuit to ground is detected, but the safety battery terminal is not triggered. The following
defect location is set in the fault memory entry of the airbag control module: "Battery cable (monitoring of shielding): implausible test result". The airbag
warning lamp in the instrument cluster is also activated.

NOTE:  All work on the airbag must only be conducted with the battery disconnected. Connect and disconnect airbag control module, sensors and gas
generators only with the battery disconnected. The airbag control module contains vehicle-specific data and must therefore be encoded before placing
into operation. Removal and installation in other vehicles is prohibited.

Charging System > < Tools and Equipment