Fig. 2 Relay Test

2. Supply 12 vdc to relay terminals 6 (-) and 9 (+). Using an ohmmeter, check for continuity between terminals 2 and 3. Refer to Fig. 2.

Continuity

Should exist when voltage is supplied.
Should NOT exist when voltage is NOT supplied.

Fig. 3 Relay Test

3. Supply 12 vdc to relay terminals 7 (-) and 3 (+). Using a voltmeter, check for voltage between terminals 2 (+) and supply battery ground terminal.

Refer to Fig. 3

Voltage

12 vdc when terminal 7 is connected.
0 vdc when terminal 7 is NOT connected.

HARNESS TEST

1. Disconnect the negative battery cable and the ECU connector.
2. Reconnect the negative battery cable and turn the key to the ON position.
3. Using a volt meter, check the voltage between ECU harness terminal 62 and ground.

Voltage

System voltage.

4. Turn the key to the OFF position.
5. Disconnect the control relay connector.
6. Using an volt meter, check the voltage between relay harness terminal 10 and ground.

Voltage

System voltage.

7. Using a ohm meter, check for continuity between relay harness terminal 8 and ECU harness connector terminal 108.

Continuity

Should exist.

8. Using a ohm meter, check for continuity between relay harness terminal 5 and ground.

Continuity

Should not exist.

9. Using a ohm meter, check for continuity between relay harness terminal 4 and ECU harness connector terminals 25 and 12.

Continuity

Non Trouble Code Components|Page 2988 > < Non Trouble Code Components