3000GT SL V6-2972cc 3.0L DOHC MFI (1997)
(A)
TEMPERATURE CONTROL WIRE INSTALLATION
Connect the temperature control wire to the blend air damper lever by following the steps below.
1. Move the temperature control lever to the right most position. ("HOT" position)
2. With the blend air damper lever pressed completely downward in the direction indicated by the arrow, connect the inner cable of the
temperature control wire to the end of the blend air damper lever and then secure the outer cable: by using a clip.
(B)
MODE SELECTION CONTROL WIRE INSTALLATION
Connect the mode selection control wire to the mode selection damper lever by following the steps below.
1. Move the mode selection lever to the defroster position.
2. With the mode selection damper lever pressed inward in the direction indicated by the arrow, connect the inner cable of the mode selection
control wire to the end of the mode selection lever and then secure the outer cable by using a clip.
(C)
AIR SELECTION CONTROL WIRE INSTALLATION
Connect the air selection control wire to the air selection damper lever by following the steps below.
1. Move the air selection control lever to the recirculation position.
2. Set the air selection damper lever as it contacts stopper.
3. Connect the inner cable of the air selection control wire to the end of the air selection lever and then secure the outer cable by using a clip.