CAUTION:  Make absolutely sure that no oil is adhering to the rubber ring of the thermostat. In addition, be careful not to fold over or scratch the
rubber ring when inserting.

>B< RADIATOR LOWER HOSE CONNECTION

1. Insert each hose as far as the projection of the water outlet fitting or water inlet fitting.

2. Align the mating marks on the radiator hose and hose clamp, and then connect the radiator hose.

INSPECTION 

THERMOSTAT CHECK

-

Check that valve closes tightly at room temperature.

-

Check for defects or damage.

-

Check for rust or encrustation on valve. Remove if any.

-

Immerse thermostat in container of water. Stir to raise water temperature and check that thermostat valve opening temperature and the temperature
with valve fully open [valve lift-over 8 mm (0.31 inch)] is at the standard value.

Standard value:
Valve opening temperature. 88°C (192°F)
Full-opening temperature: 95°C (203 °F)

NOTE:  Measure valve height when fully closed. Calculate lift by measuring the height when fully open.

Water Pump > < Mechanical Specifications|Page 1328