mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

A/C - No Air From Upper Vents|Page 3411 > < A/C - No Air From Upper Vents|Page 3409
Page 2
background image

Check that the lever moves when battery voltage is applied across terminals 1 and 3 of motor assembly side connector. Check also that the lever move in
the opposite direction when polarity is reversed.

CAUTION:  Remove the voltage when the damper is at the inside air position or outside air position.

CAUTION:  Remove the voltage if the motor does not turn when battery voltage is applied.

AIR OUTLET MODE SELECTOR DAMPER MOTOR POTENTIOMETER CHECK

During motor operation check, confirm that the resistance value between motor connector terminals 2 and 5 and 5 and 6 changes gradually in the range
of the standard value. 

Standard value: 0.18 - 4.82 kOhm

A/C - No Air From Upper Vents|Page 3411 > < A/C - No Air From Upper Vents|Page 3409