Main Relay (Computer/Fuel System) > < Intake Air Plenum|Specifications|Page 2197
Page 2
background image

>A< INTAKE MANIFOLD PLENUM GASKET 

Install so that the projection on the gasket is as shown in the diagram.

>B< PRESSURE HOSE

Secure the notched part of the pressure hose eye joint at the position where it contacts the oil pump suction connector.

INSPECTION

INTAKE MANIFOLD PLENUM 

1. Check that the surge tank is not damaged or cracked. 
2. Check that the vacuum extraction port is not clogged. If faulty, clean. 
3. Using a straight edge and thickness gauge, check the mounting surface for distortion. 

Standard value: 0.15 mm (0.006 in.) or less 
Limit: 0.2 mm (0.008 in.)

Main Relay (Computer/Fuel System) > < Intake Air Plenum|Specifications|Page 2197