Diamante V6-3.5L SOHC (2003)
ERASING DIAGNOSTIC TROUBLE CODES
When the Scan Tool is not used
With the ignition switch OFF, disconnect the battery negative terminal for 10 seconds or more.
Non-Trouble Code Procedures
IGNITION SWITCH CONTINUITY CHECK
1. Remove the instrument under cover. (Refer to Instrument Panel).
2. Disconnect the wiring connector from the ignition switch and connect an ohmmeter to the switch side connector.
3. Operate the ignition switch and check the continuity.
Check At Immobilizer-ECU - Terminal Voltage Check