ERASING DIAGNOSTIC TROUBLE CODES

When the Scan Tool is not used

With the ignition switch OFF, disconnect the battery negative terminal for 10 seconds or more.

Non-Trouble Code Procedures

IGNITION SWITCH CONTINUITY CHECK

1. Remove the instrument under cover. (Refer to Instrument Panel).
2. Disconnect the wiring connector from the ignition switch and connect an ohmmeter to the switch side connector.
3. Operate the ignition switch and check the continuity.

Check At Immobilizer-ECU - Terminal Voltage Check