19. Turn the handle of the charging valve back (valve open) and tighten the handle of the adaptor valve (valve open) to charge the system with 

refrigerant.

CAUTION:  If the service can is inverted, liquid refrigerant may be drawn into the compressor damaging it by liquid compression. Keep the
service can upright to ensure that refrigerant is charged in gas state.

20. If the refrigerant is not drawn in, turn the handle of the adaptor valve back all the way (valve closed).
21. Check for gas leaks using a leak detector.

If a gas leak is detected, re-tighten the connections, and then repeat the charging procedure from evacuation in step (12).

CAUTION:  A leak detector designed for R-134a should be used.

22. Start the engine.
23. Operate the A/C and set to the lowest temperature (MAX. COOL).
24. Fix the engine speed at 1,500 rpm.
25. Tighten the handle of the adaptor valve (valve open) to charge the required volume of refrigerant.

CAUTION:  If the service can is inverted, liquid refrigerant may be drawn into the compressor damaging it by liquid compression. Keep the
service can upright to ensure that refrigerant is charged in gas state.

26. After charging with refrigerant, turn the handle of the adaptor valve back all the way (valve closed).
27. Tighten the charging valve handle (valve closed). Remove the quick joint (for low pressure) from the low-pressure service valve.

NOTE:  If the service can is not emptied completely, keep the handles of the charging valve and adaptor valve closed for the next charging.

CORRECTING LOW REFRIGERANT LEVEL IN CASE THE SERVICE CAN IS USED

1. Install the charge valve with the handle turned all the way out (valve open) of the service can.
2. Install the adaptor value with the handle turned all the way back (valve close) to the charging valve.
3. Connect the charging hose (blue) to the adaptor valve.
4. Connect the charging hose (blue) to the quick joint (for low pressure).
5. Tighten the handle of the charge valve (valve close), and pierce the service can.
6. Turn the handle of the adaptor valve to bleed the air.

7. Install the quick joint (for low pressure) to the low pressure service valve.

NOTE:  The low-pressure service valve should be connected to the low-pressure hose.

Refrigerant Leak Repair|Page 914 > < Refrigerant Leak Repair|Page 912