(1) Disconnect the connection of the connector for the condenser fan motor.

(2) Check to be sure that the condenser fan motor operates when battery voltage is applied to terminal 3 and terminal 4 is grounded.

RESISTOR CHECK 

(1) Disconnect the connection of the connector for the resistor, and then measure the resistance between terminals.

(2) The condition can be considered satisfactory if the measured resistance is within the range noted below.

Standard value: 0.26-0.32 ohms 