mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 1732 > < Initial Inspection and Diagnostic Overview|Page 1730
Page 8
background image

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: Vehicles communication interface

-

MB991827: MUT-III USB cable

-

MB991911: MUT-III Main harness B

-

MB991813: SWS monitor kit
-

MB991806: SWS monitor cartridge

-

MB991812: SWS monitor harness (for column-ECU)

-

MB991922: Probe harness

STEP 1. Check SWS monitor kit MB991862 for proper connection.

Q: Is SWS monitor kit MB991862 connected with the column switch properly?

YES: Go to Step 2.

NO: Connect SWS monitor kit MB991862 to the column switch securely.

STEP 2. Check the power supply circuit to the ETACS-ECU.

Q: Does the system communicate with scan tool MB991958 when the ignition switch is turned to the "ON" position?

YES: Go to Step 3.

NO: Refer to Inspection Procedure A-3 "Communication with the ETACS-ECU is impossible."

STEP 3. Measure at ETACS-ECU connector C-118 and C-119 in order to check the ground circuit to the ETACS-ECU.

1. Disconnect ETACS-ECU connector C-118, C-119, and measure at the junction block side.

Initial Inspection and Diagnostic Overview|Page 1732 > < Initial Inspection and Diagnostic Overview|Page 1730