Page 12
background image

STEP 7. Check the wiring harness between ETACS-ECU connector C-118 (terminals 51 and 67) and data link connector C-29 (terminals 9 and
1).

NOTE:  Also check joint connector C-77. If joint connector C-77 is damaged, repair or replace the connector as described in Harness Connector
Inspection.

Q: Is the wiring harness between ETACS-ECU connector C-118 (terminals 51 and 67) and data link connector C-29 (terminals 9 and 1) in good
condition?

YES: Replace the ETACS-ECU. The system should communicate with the SWS monitor kit normally.

NO: Repair the wiring harness. The system should communicate with the SWS monitor kit normally.

Inspection Procedure A-2

 Communication with the Column Switch (Column-ECU) is Impossible.

Initial Inspection and Diagnostic Overview|Page 1736 > < Initial Inspection and Diagnostic Overview|Page 1734