Eclipse L4-2.4L SOHC (2004)
1. Disconnect fog light relay connector A-04X, and measure at the relay box side.
2. Measure the voltage between terminal 1, 2 and ground.
-
The measured value should be approximately 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
YES: Go to Step 7.
NO: Go to Step 5.
STEP 5. Check fog light relay connector A-04X for damage.
Q: Are fog light relay connector A-04X in good condition?
YES: Go to Step 6.
NO: Repair or replace the connector. Refer to Harness Connector Inspection. Check that the fog lights illuminate normally.