Eclipse V6-3.0L SOHC (2003)
1. Disconnect the clock spring connector C-84.
2. Measure resistance between terminal 3 and ground.
-
The measured value should be 2 Ohms or less.
Q: Does the measured resistance value correspond with this range?
YES: Go to Step 7.
NO: Go to Step 5.
STEP 5. Check the clock spring connector C-84 and radio and cd player connector C-21 for damage.
Q: Is clock spring connector C-84 and radio and cd player connector C-21 in good condition?
YES: Go to Step 6.