<<A>> LEFT BANK HEATED OXYGEN SENSOR (FRONT) REMOVAL

Use special tool MD998770 to remove the oxygen sensor.

INSTALLATION SERVICE POINT

LEFT BANK HEATED OXYGEN SENSOR (FRONT) INSTALLATION

Use special tool MD998770 to installation the oxygen sensor.

INSPECTION

Check the following points; replace the part if a problem is found.

Exhaust Manifold Check

1. Check for damage or cracking of any part.
2. Using a straight edge and a feeler gauge, check for distortion of the cylinder head installation surface.

Standard value: 0.15 mm (0.006 inch) or less 

Limit: 0.20 mm (0.008 inch)