Eclipse V6-3.0L SOHC (2003)
2. Measure the resistance between terminal 6 and ground by backprobing.
-
The measured value should be 2 Ohms or less.
Q: Does the measured resistance value correspond with this range?
YES: Go to Step 4.
NO: Go to Step 2.
STEP 2. Check the multi-center display connector C-09 for damage.
Q: Is the multi-center display connector C-09 in good condition?
YES: Go to Step 3.
NO: Repair or replace the connector. Refer to Harness Connector Inspection.