mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Information Bus > < Oscilloscope Check|Page 2052
Page 2
background image

4. Connect the positive (+) terminal of a power supply (approximately 6 volts) to terminal 2 and the terminal 5.
5. Connect the negative (-) terminal of the power supply to each clip as described in the following steps. Then check whether or not the stepper motor

vibrates slightly as it operates.
1. Connect the negative terminal of the power supply to terminal 1 and terminal 4.
2. Connect the negative terminal of the power supply to terminal 3 and terminal 4.
3. Connect the negative terminal of the power supply to terminal 3 and terminal 6.
4. Connect the negative terminal of the power supply to terminal 1 and terminal 6.
5. Connect the negative terminal of the power supply to terminal 1 and terminal 4.
6. Repeat the tests in sequence from (5) to (1) to test opposite movement of the IAC.

6. If vibration is detected during the test, the stepper motor can be considered to be normal.