mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2117 > < Initial Inspection and Diagnostic Overview|Page 2115
Page 53
background image

1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. When the ignition switch is turned to the "ON" position.
4. Operate the MUT-II according to the procedure below to display "ECU COMM CHECK."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHECK."

5. Scan tool MB991502 should show "OK" on the "ETACS ECU" menu.

Q: Is "OK" displayed on the "ETACS ECU" menu?

YES: Go to Step 2.

NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is impossible."

STEP 2. Check the input signal by using "DATA LIST" of the SWS monitor.

Turn the ignition switch to the "ON" position before checking input signals from the ignition switch (IG1). Operate the MUT-II according to the
procedure below to display "ETACS ECU."

1. Select "SYSTEM SELECT."
2. Select"SWS."
3. Select "SWS MONITOR."
4. Select "DATA LIST."
5. Select "ETACS ECU."

Initial Inspection and Diagnostic Overview|Page 2117 > < Initial Inspection and Diagnostic Overview|Page 2115