mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2166 > < Initial Inspection and Diagnostic Overview|Page 2164
Page 102
background image

STEP 5. Check at front power window sub-switch connector E-05 in order to check the power window relay circuit of the power supply to the
power window sub-switch.

1. Disconnect power window sub-switch connector E-05, and measure at the harness side.

2. Measure the voltage between terminal 7 and ground.

-

The measured value should be approximately 12 volts (battery positive voltage).

Q: Does the measured voltage correspond with this range?

YES: Go to Step 8.

NO: Go to Step 6.

STEP 6. Check power window relay connector C-116 and front power window sub-switch connector E-05 for damage.

Q: Are power window relay connector C-116 and power window sub-switch connector E-05 in good condition?

Initial Inspection and Diagnostic Overview|Page 2166 > < Initial Inspection and Diagnostic Overview|Page 2164