2. Operate the MUT-II as follows:

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."

3. Push the transmitter "LOCK", "UNLOCK" or "TRUNK" switch.
4. Check that scan tool MB991502 sounds

Q: When the transmitter "LOCK", "UNLOCK" or "TRUNK" switch is pushed, does scan tool MB991502 sound?

YES: Replace the ETACS-ECU. All the doors can be locked or unlocked by means of the transmitter. And the trunk lid opened by means of
the transmitter.

NO: Refer to Inspection Procedure P-13 "The ETACS-ECU does not receive signal from lock, unlock, panic or trunk switch".

STEP 5. Check the central door locking system.

Q: Does the central door locking system work normally?

YES: Go to Step 6,

NO: Refer to Inspection Procedure C-1 "Central door locking system does not work at all."

STEP 6. Check the input signal (by using the Pulse check).

Check the input signals from the transmitter.

CAUTION:  To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991502.

1. Connect scan tool MB991502 to the data link connector.
2. Operate the MUT-II as follows:

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."

3. Push the transmitter "LOCK" or "UNLOCK" switch.
4. Check that scan tool MB991502 sounds

Q: When the transmitter "LOCK" or "UNLOCK" switch is pushed, does scan tool MB991502 sound?

YES: Replace the ETACS-ECU. All the doors can be locked or unlocked by means of the transmitter.

NO: Refer to Inspection Procedure P-13 "The ETACS-ECU does not receive signal from lock, unlock, panic or trunk switch".

STEP 7. Check the input signal (by using the Pulse check).

Check the input signals from the transmitter.

CAUTION:  To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or