mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2185 > < Initial Inspection and Diagnostic Overview|Page 2183
Page 121
background image

1. Connect scan tool MB991502 to the data link connector.
2. Operate the MUT-II as follows:

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."

3. Check the scan tool MB991502 sounds or not.

4. If the switches which are applicable for the input signal check, are operated.

Q: When the key reminder switch and the hazard warning light switch are operated, does scan tool MB991502 sound in each case?

YES: Replace the ETACS-ECU. Check that the encrypted code can be registered in the transmitter.

NO:
-

Scan tool MB991502 does not sound when the ignition key is removed and reinserted: Refer to Inspection Procedure O-1 "ETACS-ECU
does not receive a signal from the key reminder switch."

-

Scan tool MB991502 does not sound when the hazard warning light switch is turned from "OFF" to "ON": Refer to Inspection Procedure
O-2 "ETACS-ECU does not receive a signal from the hazard warning light switch."

STEP 3. Check the transmitter.

Q: When the transmitter's battery is replaced, can the encrypted code be registered?

YES: No action to be taken.

NO: Replace the transmitter. If the encrypted code can not be registered by means of the new transmitter, replace the ETACS-ECU. Check that the
encrypted code can be registered in the transmitter.

Inspection Procedure F-1

Sunroof: Sunroof Does Not Operate.

Initial Inspection and Diagnostic Overview|Page 2185 > < Initial Inspection and Diagnostic Overview|Page 2183