mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2212 > < Initial Inspection and Diagnostic Overview|Page 2210
Page 148
background image

-

Damaged harness wires and connectors

DIAGNOSIS

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

-

MB991862: SWS Monitor Kit

STEP 1. Check the input signal by using "DATA LIST" of the SWS monitor.

Turn the ignition switch to the ACC position before checking input signals from the windshield wiper switch.

CAUTION:  To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991502. Also connect SWS monitor kit MB991862 after turning on scan tool MB991502.

1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. Operate the MUT-II according to the procedure below to display "COLUMN ECU."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "DATA LIST."
5. Select "COLUMN ECU."

4. Check that normal conditions are displayed on the items described in the table.

Q: Does the scan tool display all items "INT WIPER SW", "LO WIPER SW", "HI WIPER SW" and "MIST WIPER SW" as normal condition?

YES: Go to Step 2.

NO: Refer to Inspection Procedure O-8 "ETACS-ECU does not receive a signal from the windshield mist switch."

Initial Inspection and Diagnostic Overview|Page 2212 > < Initial Inspection and Diagnostic Overview|Page 2210