2. Measure the voltage between terminal 21 and ground.
-
The measured value should be 12 volts (battery positive voltage).
Q: Does the measured voltage correspond with this range?
YES: Go to Step 8.
NO: Go to Step 6.
STEP 6. Check combination meter connector C-42 for damage.
Q: Is combination meter connector C-42 in good condition?
YES: Go to Step 7.
NO: Repair or replace the connector. Refer to Harness Connector Inspection. Check that the high-beam indicator light illuminates normally.