mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2342 > < Initial Inspection and Diagnostic Overview|Page 2340
Page 278
background image

1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. Operate the MUT-II according to the procedure below to display "TURN SIG.RH."

1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "FUNCTION DIAGNOSIS"
5. Select "TURN SIGNAL."
6. Select "TURN SIG.RH."

4. Check that normal conditions are displayed on the items described in the table.

Q: Does the scan tool display the items "T/S RH SW" and "IG SW (IG1)" as normal condition?

YES: Go to Step 8.

NO:
-

The scan tool does not show the respective normal condition for item "T/S RH SW." Refer to Inspection Procedure O-7 "ETACS-ECU
does not receive any signal from the taillight switch, the headlight switch, the passing light switch, the dimmer switch, the turn-signal light
switch or switch."

-

The scan tool does not show the respective normal condition for item "IG SW (IG1)." Refer to Inspection Procedure O-2 "ETACS-ECU
does not receive a signal from the ignition switch (IG1)."

STEP 8. Check the input signal by using "FUNCTION DIAGNOSIS" of the SWS monitor.

Initial Inspection and Diagnostic Overview|Page 2342 > < Initial Inspection and Diagnostic Overview|Page 2340