background image

2. Measure the voltage between terminal 1, 2 and ground.

-

The measured value should be approximately 12 volts (battery positive voltage).

Q: Does the measured voltage correspond with this range?

YES: Go to Step 7.

NO: Go to Step 5.

STEP 5. Check fog light relay connector A-04X for damage.

Q: Are fog light relay connector A-04X in good condition?

YES: Go to Step 6.

NO: Repair or replace the connector. Refer to Harness Connector Inspection. Check that the fog lights illuminate normally.

STEP 6. Check the wiring harness between fog light relay connector A-04X (terminals 1 and 2) and the battery.

Q: Is the wiring harness between fog light relay connector A-04X (terminals 1 and 2) and the battery in good condition?

YES: No action to be taken.

NO: Repair the wiring harness. Check that the fog lights illuminate normally.