mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2385 > < Initial Inspection and Diagnostic Overview|Page 2383
Page 321
background image

CIRCUIT OPERATION

The ETACS-ECU illuminates the dome light, the luggage compartment light <ECLIPSE> and the trunk light <ECLIPSE SPYDER> according to the
following signals:

-

Ignition switch (IG1): ON or OFF

-

Key reminder switch: ON or OFF

-

Front door switch: ON or OFF

-

Driver's door lock actuator switch: ON or OFF

-

Liftgate latch switch (vehicles with theft-alarm system) or liftgate light switch (vehicles without theft-alarm system): ON or OFF <ECLIPSE>

-

Trunk lid latch switch (vehicles with theft-alarm system) or trunk light switch (vehicles without theft-alarm system): ON or OFF <ECLIPSE
SPYDER>

-

Interior light loaded signal: ON

TECHNICAL DESCRIPTION (COMMENT)

If the dome light, the luggage compartment light <ECLIPSE> and trunk light <ECLIPSE SPYDER> do not illuminate normally, the dome light bulb(s)
may be burned out or the input circuit system from the switches, the power supply lines to the switches or the ETACS-ECU may be defective (refer to
"CIRCUIT OPERATION").

TROUBLESHOOTING HINTS

-

Malfunction of the key reminder switch

-

Malfunction of the door switch

-

Malfunction of the driver's door lock actuator switch

-

Malfunction of the dome light

-

Malfunction of the liftgate latch switch or liftgate light switch <ECLIPSE>

-

Malfunction of trunk lid latch switch or trunk light switch <ECLIPSE SPYDER>

-

Malfunction of the ETACS-ECU

-

Damaged harness wires or connectors

DIAGNOSIS

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

-

MB991862: SWS Monitor Kit

STEP 1. Use scan tool to select "ECU COMM CHECK" on the SWS monitor display.

CAUTION:  To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991502. Also connect SWS monitor kit MB991862 after turning on scan tool MB991502.

Initial Inspection and Diagnostic Overview|Page 2385 > < Initial Inspection and Diagnostic Overview|Page 2383