Eclipse V6-3.0L SOHC (2003)
STEP 3. Check the input signal by using "DATA LIST" of the SWS monitor.
Check the input signals from the following switches:
-
Ignition switch: OFF
-
Driver's or front passenger's door: open Operate the MUT-II according to the procedure below to display "ETACS ECU."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "DATA LIST."
5. Select "ETACS ECU."
Check that normal conditions are displayed on the items described in the table.
Q: Does the scan tool display the items "IG SW (IG1)" and "FRONT DOOR SW" as normal condition?
YES: Go to Step 4.
NO:
-
Normal condition is not displayed for "IG SW (IG1)": Refer to Inspection procedure O-2 "ETACS-ECU does not receive a signal from the
ignition switch (IG1)."
-
Normal condition is not displayed for "FRONT DOOR SW": Refer to Inspection procedure O-6 "ETACS-ECU does not receive a signal from the
driver's or the front passenger's door switch."