mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2439 > < Initial Inspection and Diagnostic Overview|Page 2437
Page 375
background image

-

Interior light automatic-shutdown function

TECHNICAL DESCRIPTION (COMMENT)

If the signal is not normal, the equipment and functions), which are described in "CIRCUIT OPERATION", do not work normally.

TROUBLESHOOTING HINTS

-

Malfunction of the ETACS-ECU

-

Damaged harness wires or connectors

DIAGNOSIS

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

STEP 1. Measure at ETACS-ECU connector C-119 in order to check the line from the ignition switch (ACC).

1. Disconnect ETACS-ECU connector C-119, and measure at the junction block side.
2. Turn the ignition switch to the "ACC" position.

3. Measure the voltage between terminal 4 and ground.

-

The measured value should be approximately 12 volts (battery positive voltage).

Q: Does the measured voltage correspond with this range?

YES: Replace the ETACS-ECU. If the equipment, which are described in "CIRCUIT OPERATION", work normally, the input signal from
the ignition switch (ACC) should be normal.

NO: Go to Step 2.

Initial Inspection and Diagnostic Overview|Page 2439 > < Initial Inspection and Diagnostic Overview|Page 2437