Eclipse V6-3.0L SOHC (2003)
1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate the MUT-II according to the procedure below to display "ECU COMM CHECK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHECK."
5. Scan tool MB991502 should show "OK" on the "ECU COMM CHECK" menu.
Q: Is "OK" displayed on the "COLUMN ECU" menu?
YES: Go to Step 2.
NO: Refer to Inspection Procedure A-2 "Communication with column switch (column-ECU) is impossible."