background image

2. No continuity should be present between key reminder switch terminal 4 and each terminal other than terminal 6, and between key reminder switch

terminal 6 and each terminal other than terminal 4.

Q: Is continuity present between any two terminals?

YES: Replace the ETACS-ECU. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal from the
key reminder switch should be normal.

NO: Replace the key reminder switch. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal
from the key reminder switch should be normal.

Inspection Procedure P-2

The ETACS-ECU Does Not Receive Any Signal From The Hazard Warning Light Switch.

Hazard Warning Switch Input Circuit Part 1

Hazard Warning Switch Input Circuit Part 2

CIRCUIT OPERATION

The ETACS-ECU operates the following functions or systems according to signal from the hazard warning light switch:

-

Hazard warning light