Eclipse V6-3.0L SOHC (2003)
2. No continuity should be present between key reminder switch terminal 4 and each terminal other than terminal 6, and between key reminder switch
terminal 6 and each terminal other than terminal 4.
Q: Is continuity present between any two terminals?
YES: Replace the ETACS-ECU. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal from the
key reminder switch should be normal.
NO: Replace the key reminder switch. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal
from the key reminder switch should be normal.
Inspection Procedure P-2
The ETACS-ECU Does Not Receive Any Signal From The Hazard Warning Light Switch.
Hazard Warning Switch Input Circuit Part 1
Hazard Warning Switch Input Circuit Part 2
CIRCUIT OPERATION
The ETACS-ECU operates the following functions or systems according to signal from the hazard warning light switch:
-
Hazard warning light