mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2529 > < Initial Inspection and Diagnostic Overview|Page 2527
Page 465
background image

STEP 5. Check the wiring harness between power window main switch E-12 (terminal 9) and ground.

NOTE:  Also check intermediate connector C-91. If intermediate connectors C-91 is damaged, repair or replace the connector as described in Harness
Connector Inspection.

Q: Is the wiring harness between power window main switch connector E-12 (terminal 9) and ground in good condition?

YES: No action to be taken.

NO: Repair the wiring harness. If the central door locking system works normally, input signal from the door lock switch should be normal.

STEP 6. Check power window main switch connector E-12 and ETACS-ECU connector C-117 for damage.

Q: Are power window main switch connector E-12 and ETACS-ECU connector C-117 in good condition?

YES: Go to Step 7.

NO: Repair or replace the connector. Refer to Harness Connector Inspection. If the central door locking system works normally, input signal from the
door lock switch should be normal.

Initial Inspection and Diagnostic Overview|Page 2529 > < Initial Inspection and Diagnostic Overview|Page 2527