Malfunction Lamp / Indicator: Description and Operation
Warning Light Circuit Connector Lock Switch

The switch is a mechanism that shorts the power supply terminal to the ground terminal automatically in the warning light circuit when the connector is
disconnected. Its structure is similar to the squib circuit connector shorting mechanism.