mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2898 > < Initial Inspection and Diagnostic Overview|Page 2896
Page 56
background image

NO: Check the combination meter connector, and repair if necessary. If the combination meter connector is in good condition, replace the
combination meter.

STEP 9. Check the ETACS-ECU for short circuit. Measure the resistance at ETACS-ECU connector C-218.

1. Disconnect the negative battery terminal.

2. Disconnect ETACS-ECU connector C-218, and measure the resistance at the component side of ETACS-ECU connector C-218.

3. Measure the resistance between ETACS-ECU connector terminals 72 and 73.

OK: 1 k ohms or more

Q: Is the check result normal?

YES: Check the ETACS-ECU connector, and repair if necessary. If the ETACS-ECU connector is in good condition, repair the wiring harness
between joint connector (3) and the ETACS-ECU connector.

NO: Check the ETACS-ECU connector, and repair if necessary. If the ETACS-ECU connector is in good condition, replace the ETACS-ECU.
When the ETACS-ECU is replaced, register the encrypted code. Refer to Encrypted Code Registration Criteria Table in Antitheft and Alarm
Systems.

STEP 10. Check the A/C-ECU for short circuit. Measure the resistance at A/C-ECU connector C-14 <manual air conditioning system> or C-15
<automatic air conditioning system>.

CAUTION:  A digital multimeter should be used.

1. Disconnect the negative battery terminal.

Initial Inspection and Diagnostic Overview|Page 2898 > < Initial Inspection and Diagnostic Overview|Page 2896