Eclipse FWD L4-1997cc 2.0L DOHC MFI (1997)
Ignition Switch: Component Tests and General Diagnostics
Ignition Switch Continuity Check
Ignition Switch Continuity Check - Chart
1. Remove the instrument under cover.
2. Remove the column cover lower and upper.
3. Disconnect the wiring connector from the ignition switch and connect an ohmmeter to the switch side connector.
4. Operate the ignition switch and check the continuity.