mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Transmission Cooler, A/T > < Fluid Leakage|Page 2779
Page 1
background image

Transmission Control System Relay: Testing and Inspection

EATX RELAY CHECK

1. Remove the EATX relay.

2. Check the continuity between the EATX relay terminals 4 and 6.

3. Use jumper leads to connect EATX relay terminal 4 to the battery (+) terminal and terminal 6 to the battery (-) terminal.

4. Check the continuity between EATX relay terminals 2 and 8 while connecting and disconnecting the jumper lead at the battery (-) terminal.

Transmission Cooler, A/T > < Fluid Leakage|Page 2779