Simplified Wiring System: Initial Inspection and Diagnostic Overview

Before Carrying Out Troubleshooting

Before carrying out troubleshooting, check the following two items.

*

Make sure that the ETACS-ECU, the junction block (J/B), the front-ECU and the engine compartment relay box are connected securely.

*

Make sure that fuses and fusible links related to relevant systems are not blown.

How to Check ECU's

HOW TO CHECK ECUs

1. Use the scan tool and the SWS monitor kit to check ECUS, (Refer to MUT-II Reference Manual)
2. The following ECUs can be checked by using the scan tool and the SWS monitor kit.

NOTE:  The "ECU CHECK" function checks a communication status of ECUs "NG" does not always mean ECU malfunction. If a malfunction is
found by the "ECU CHECK", proceed "Symptom Procedure".

How to Cope With Intermittent Malfunctions

Most intermittent malfunctions occur under certain conditions. If those conditions can be identified, the cause will be easier to find.

TO COPE WITH INTERMITTENT MALFUNCTION;

1. Ask the customer about the malfunction

Ask what it feels like, what it sounds like, etc. Then ask about driving conditions, weather, frequency of occurrence, and so on.

2. Determine the conditions from the customer's responses

Typically, almost all intermittent malfunctions occur from conditions like vibration, temperature and/or moisture change, poor connections. From
the customer's replies, it should be reasoned which condition is influenced.

3. Use simulation test

In the cases of vibration or poor connections, use the simulation tests below to attempt to duplicate the customer's complaint. Determine the most
likely circuit(s) and perform the simulation tests on the connectors and parts of that circuit(s). Be sure to use the inspection procedures provided
for diagnostic trouble codes and trouble symptoms.
For temperature and/or moisture conditions related intermittent malfunctions, using common sense, try to change the conditions of the suspected
circuit components, then use the simulation tests below.

Initial Inspection and Diagnostic Overview|Page 1913 > < Simplified Wiring System <--> [Information Bus]|Service Precautions|Page 1910