mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2009 > < Initial Inspection and Diagnostic Overview|Page 2007
Page 92
background image

Inspection Procedure D-5

Power Window: Door Window (RH) does not Work by Operating Power Window Main Switch.

Power Window (RH) Circuit

CIRCUIT OPERATION

When you operate each power window switch for front passenger's (incorporated in the power window main switch), the corresponding power window
motor operates, thus causing each power window to close or open.

TECHNICAL DESCRIPTION (COMMENT)

If the corresponding power window (RH) opens and closes normally when power window sub-switch is operated, the power window main switch may be
defective.

TROUBLESHOOTING HINTS

-

Malfunction of power window main switch

DIAGNOSIS

Check that power window sub-switches operate normally.

Q: Does the power window sub-switch operate the power window (RH)?

YES: Replace the power window main switch. When the power window main switch is operated, the power window (RH) should open or close
normally.

NO: Refer to Symptom Chart before resolving this trouble.

Inspection Procedure E-1

Keyless Entry System: Keyless Entry System does not Operate.

Initial Inspection and Diagnostic Overview|Page 2009 > < Initial Inspection and Diagnostic Overview|Page 2007