If the signal is not normal, the equipment or systems, which are described in "CIRCUIT OPERATION", do not work normally.

TROUBLESHOOTING HINTS

-

Malfunction of the hazard warning light switch

-

Malfunction of the ETACS-ECU

-

Damaged harness wires or connectors

DIAGNOSIS

Required Special Tools:

-

MB991223: Test Harness Set

-

MB991502: Scan Tool (MUT-II)

STEP 1. Check the hazard warning light switch.

Q: Is the hazard warning light switch in good condition?

YES: Go to Step 2.

NO: Replace the hazard warning light switch. If the equipment, which are described in "CIRCUIT OPERATION", work normally, the input signal
from the hazard warning light switch should be normal.

STEP 2. Measure at hazard warning light switch connector C-10 in order to check the ground circuit to the hazard warning light switch.

1. Disconnect hazard warning light switch connector C-10, and measure at the wiring harness side.

2. Measure the resistance value between terminal 2 and ground.

-

The measured value should be 2 ohm or less.

Q: Does the measured resistance value correspond with this range?

YES: Go to Step 5.

NO: Go to Step 3.

Initial Inspection and Diagnostic Overview|Page 2265 > < Initial Inspection and Diagnostic Overview|Page 2263