mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < Positive Crankcase Ventilation Valve|Locations
Page 1
background image

Positive Crankcase Ventilation Valve: Testing and Inspection

1. Insert a thin rod into the positive crankcase ventilation valve from the side shown in the illustration (rocker cover installation side), and move the

rod back and forth to confirm that the plunger moves.

2. If the plunger does not move, the valve is clogged. In this case, clean or replace the valve.

Fuel Delivery and Air Induction > < Positive Crankcase Ventilation Valve|Locations