Replacement Clockspring Alignment As Per Manual Update TSB-08-52B-001 (Part 2)

1. Turn the clockspring clockwise fully.
2. Turn the clockspring anti-clockwise (counter-clockwise) approx. 3/4 turns to align the mating marks.
3. Check that the white or yellow roller can be seen from the window for checking the neutral point when the mating marks are aligned.

NOTE:  If the white or yellow roller cannot be seen or black roller can be seen, the neutral point is not aligned correctly.

4. Install the clockspring to the column switch.

CAUTION:  If the clock spring's mating marks are not properly aligned, the steering wheel may not be completely rotational during a turn, or the
flat cable within the clock spring may be severed, obstructing normal operation of the SRS.

Step 3: Steering Wheel Installation
1. Before installing the steering wheel, be sure to first turn the vehicle's front wheels to the straight-ahead position and align the mating marks of the 

clock spring.

CAUTION:  Be sure when installing the steering wheel, that the harness of the clock spring does not become caught or tangled.

2. After installing, turn the steering wheel all the way in both directions to confirm that steering is normal.

Air Bag Module (Driver's Side)

Step 2: Air Bag Module (Driver's Side) Installation

Install the air bag module, taking care that the wiring is not pinched.

POST-INSTALLATION INSPECTION

1. After installing the clock spring, the steering wheel, the column covers and the air bag module, check steering wheel for noise, binds or difficult

operation.

2. Reconnect the negative battery terminal. Turn the ignition key to the "ON" position. Does the "SRS" warning light illuminate for about 7 seconds,

turn OFF and then remain OFF? If yes, SRS system is functioning properly. If no, consult Diagnostic Function.

INSPECTION 

Restraints - Revised Clockspring Alignment Procedure|Page 4344 > < Restraints - Revised Clockspring Alignment Procedure|Page 4342