Fillpipe Restrictor: Testing and Inspection

Fill Pipe Restrictor

 

Use dowel gauge to check restrictor opening [1].

 

Inspect for tampering, broken flap, excessive wear etc.

 
REMARKS:

 

[1]  N&W Manufacturing part number FRG-95, or equivalent, (must be made of non-sparking material, 1552 alloy suggested).

 

-

Minimum tool diameter .9375"

-

Maximum tool diameter .9500"