mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Compressor Pulley|Removal and Installation|Page 4107 > < Compressor Pulley|Removal and Installation
Page 2
background image

B

COMPRESSOR DRIVE BELT REMOVAL
1. Loosen bolt "A" for holding the tension pulley.
2. Loosen bolt "B" for adjustment.
3. Remove the compressor drive belt.

C

COMPRESSOR REMOVAL
When doing this work, be careful not to spill the compressor oil.

INSTALLATION SERVICE POINT

A

COMPRESSOR INSTALLATION
If a new compressor is installed, first adjust the amount of oil according to the procedures described below, and then install the compressor.
1. Measure the amount 

{X cm3 (x fl.oz.)} of oil within the removed compressor.

2. Drain (from the new compressor) the amount of oil calculated according to the following formula, and then install then new compressor.

New compressor oil amount 

170 cu cm - X cu cm = Y cu cm (5.7 fl.oz. - x fl.oz. = y fl.oz.)

NOTE:
1.

Y cu cm (y fl.oz.) indicates the amount of oil in the refrigerant line, the condenser, the evaporator etc.

2. When replacing the following parts as well as the compressor, subtract the rated oil amount of the each part from 

Y cu cm (Y fl.oz.)

and discharge from the new compressor.
Quantity
Evaporator: 

60 cu cm (2.03 fl.oz.)

Condenser: 

15 cu cm (.51 fl.oz.)

Suction hose: 

10 cu cm (.34 fl.oz.)

Receiver: 

10 cu cm (.34 fl.oz.)

Compressor Pulley|Removal and Installation|Page 4107 > < Compressor Pulley|Removal and Installation