mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2136 > < Initial Inspection and Diagnostic Overview|Page 2134
Page 77
background image

Q: Does the tone alarm of scan tool MB991502 sound when the input signal enters?

YES: Replace the ETACS-ECU. The rear wiper should stop at the predetermined park position.

NO: Check the rear wiper auto-stop signal input circuit. Refer to Inspection Procedure O-8.

STEP 3. Check the input signal (by using a voltmeter).

Check that the rear wiper auto-stop signal is sent to the ETACS-ECU.

NOTE:  Whenever the rear wiper begins to work, a signal is sent to the ETACS-ECU

1. Use special tool MB991529 to connect a voltmeter between ground terminal 4 or 5 and ETACS-ECU terminal 9 of the data link connector.
2. Check that the voltmeter indicator deflects once when the input signal enters.

Q: Does the voltmeter Indicator deflect?

YES: Replace the ETACS-ECU. The rear wiper should stop at the predetermined park position.

NO: Check the rear wiper auto-stop signal input circuit. Refer to Inspection Procedure O-8.

Inspection Procedure H-3

Rear Wiper and Washer: When the Selector Lever Is Moved to "R" Position During the Rear Wiper Operation, the Rear Wiper does not
operate at the continuous mode

TECHNICAL DESCRIPTION (COMMENT)

The ETACS-ECU operates the rear wiper consecutively twice when the selector lever is moved to "R" position while the rear wiper is turned on. If the
rear wiper does not work consecutively twice, the park/neutral position switch ("R" position) may be defective.

TROUBLESHOOTING HINTS

-

Malfunction of the park/neutral position switch

-

Malfunction of the ETACS-ECU

-

Damaged harness wires or connectors

DIAGNOSIS

Required Special Tools:

-

MB991502: Scan Tool (MUT-II)

-

MB991529: Diagnostic Trouble Code Check Harness.

STEP 1. Check method of the input signal

Q: Which is to be used, the scan tool or the voltmeter to check the input signal?

Scan tool MB991502 : Go to Step 2.
Voltmeter: Go to Step 3.

STEP 2. Check the input signal (by using scan tool MB991502).

Check the input signals from the park/neutral position switch "R" position.

Initial Inspection and Diagnostic Overview|Page 2136 > < Initial Inspection and Diagnostic Overview|Page 2134