2. Set the manual calibration, and drive the vehicle in a circle. See: Adjustments
Q: Is the manual calibration performed successfully?
YES : Go to Step 5.
NO : Go to Step 3.
STEP 3. Demagnetize the vehicle.
In certain circumstances the vehicle body may be magnetized. For how to demagnetize, Driver/Vehicle Information Display/Service and Repair. See:
Service and Repair/Vehicle Magnetic Compensation
Q: Is the demagnetization performed successfully?
YES : Go to Step 4.
NO : Replace multi-center display unit (middle grade type) and go to step 4.
STEP 4. Perform the manual calibration again.
Q: Is the manual calibration performed successfully?
YES : Go to Step 5.
NO : Replace multi-center display unit (middle grade type) and then go to Step 1.
STEP 5. Retest the system.
Q: Is the check result satisfactory?
YES : The procedure is complete.
NO : Replace multi-center display unit (middle grade type) and then go to Step 1.