background image

REMOVAL SERVICE POINTS

<<A>> RESERVE TANK ASSEMBLY REMOVAL

Position the reserve tank assembly out of the way. The reserve tank assembly cannot be removed completely from the engine compartment. 

<<B>> FLEXIBLE SUCTION HOSE AND LIQUID PIPE A DISCONNECTION

CAUTION:  As the compressor oil and receiver are highly moisture absorbent, use a non-porous material to plug the hose and nipples.

To prevent the entry of dust or other foreign bodies, plug the dismantled hose and condenser assembly nipples. 

INSTALLATION SERVICE POINT 

>>A<< CONDENSER INSTALLATION

When replacing the condenser, refill it with a specified amount of compressor oil and install it to the vehicle.

-

Compressor oil: SUN PAG 56

-

Quantity: 15 cu.cm (0.5 fl.oz)