Accuracy Check of Occupant Classification Sensor|Page 5334 > < Accuracy Check of Occupant Classification Sensor|Page 5332
Page 6
background image

10. If the tolerance level between the sensor output and the input value is within 4.9 kg (11 pounds), the screen for the accuracy check completion

is displayed, and if more than 4.9 kg (11 pounds), the screen for abnormal condition is displayed.

NOTE:  If the abnormal condition is displayed, check the seat installation condition. If the seat is improperly installed, install it properly and
repeat from step (4).

11. When the abnormal condition is displayed, press the OK button and go to the calibration screen. Return to step 9. when the cancel button is

pressed.)

12. Check the seat installation condition and carry out the friction removal in step (2) again, and press the OK button. When the execution dialog is

displayed, press the OK button again to execute the calibration.

13. The calibration has been completed when the screen as shown in the illustration is displayed. Press the OK button to return to the screen of

step (4), and carry out the same procedure.

4. If the accuracy testing does not complete, an intermittent malfunction is suspected. (Refer to How to Use Troubleshooting/Inspection Service

Points - How to Cope with Intermittent Malfunction.)