Accuracy Check of Occupant Classification Sensor|Page 5449 > < Accuracy Check of Occupant Classification Sensor|Page 5447
Page 4
background image

5. If the tolerance level between the sensor output and the input value is within 4.9 kg (11 pounds), the screen for the accuracy check completion

is displayed, and if more than 4.9 kg (11 pounds), the screen for abnormal condition is displayed.

NOTE:  When the screen for the accuracy check of 0 kg (0 pound) is displayed, go to step (9). If the abnormal condition is displayed, check
the seat installation condition. If the seat is improperly installed, install it properly and carry out the operation in step (4) again.

6. When the abnormal condition is displayed, press the OK button and go to the calibration screen. If the cancel button is pressed the screen

returns to step (4).

7. Unload the weight, check the seat installation condition and carry out the friction removal in step (2) again, and press the OK button. When the

execution dialog is displayed, press the OK button again to execute the calibration.

8. The calibration has been completed when the screen as shown in the illustration is displayed. Press the OK button to return to the screen of

step (4), and carry out the same procedure.