mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Refrigerant Temperature Sensor > < Built Before December 2003|Page 379
Page 1
background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection

SIMPLE INSPECTION OF THE A/C PRESSURE SENSOR

Required Special Tools:  

-

MB991658: Test Harness

1. Assemble a gauge manifold on the high pressure service valve.

2. Disconnect the A/C pressure sensor connector and connect special tool MB991658 as shown in the illustration.
3. Turn ON the engine and then turn ON the air conditioner switch.

4. At this time, check to see that the voltage of A/C pressure sensor terminal No.2 reflects the specifications of the figure.

NOTE:  The allowance shall be defined as ±5%.

Refrigerant Temperature Sensor > < Built Before December 2003|Page 379