mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7691 > < Initial Inspection and Diagnostic Overview|Page 7689
Page 451
background image

1. Disconnect key reminder switch connector C-310 and measure the resistance available at the equipment side of the connector.
2. Check for continuity between key reminder switch connector C-310 terminal 4 and each of the other terminals.

Q: Does the continuity exist between the terminals?

NO: Replace the ETACS-ECU. If the functions described in "CIRCUIT OPERATION" work normally, the input signal from the key reminder
switch should be normal.

YES: Replace the key reminder switch. If the functions described in "CIRCUIT OPERATION" work normally, the input signal from the key
reminder switch should be normal.

Inspection Procedure P-2

INSPECTION PROCEDURE P-2: ETACS-ECU does not receive any signal from the hazard warning light switch.

Hazard Warning Light Switch Input Circuit

CIRCUIT OPERATION

The ETACS-ECU operates the following functions or systems according to signal from the hazard warning light switch:

-

Turn-signal light buzzer

-

Hazard warning light

-

Keyless entry system (registering the encrypted code)

Initial Inspection and Diagnostic Overview|Page 7691 > < Initial Inspection and Diagnostic Overview|Page 7689