Starter Solenoid: Testing and Inspection
Magnetic Switch Pull-In Test

Fig. 5  Testing Magnetic Switch

1.

Disconnect field coil wire from ``M'' terminal of magnetic switch, Fig. 5.

2.

Connect a 12 volt battery between ``S'' and ``M'' terminals. This test must be performed in less than 10 seconds to prevent coil from burning
out.

3.

If pinion moves out, then pull-in coil is operating correctly. If pinion does not move out, replace magnetic switch.

Magnetic Switch Pull-In Test|Page 3930 > < Starter Relay|Locations|Page 3925